1[목차]
2== 개요 ==
3HP 서버 전용 점검 명령어를 정리한 문서이다.
4
5
6== Gen6~8 이하 명령어 ==
7디스크 점검
8> hpacucli ctrl all show config
9
10캐시배터리 점검
11> hpacucli ctrl all show status
12
13== Gen9 서버 명령어 ==
14디스크 점검
15> hpssacli ctrl all show config
16
17디스크 점검
18> hpssacli ctrl all show status
19
20== Gen10 서버 명령어 ==
21디스크 점검
22> ssacli ctrl all show config
23
24 캐시배터리 점검
25> ssacli ctrl all show status
26
27===# 정상 출력 #===
28># xxx ctrl all show config [br] [br] HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PWXKV0CRHXXXXX) [br] [br] Internal Drive Cage at Port 1I, Box 3, OK [br] Internal Drive Cage at Port 2I, Box 3, OK [br] [br] Port Name: 1I (Mixed) [br] Port Name: 2I (Mixed) [br] [br] Array A (SAS, Unused Space: 0 MB) [br] logicaldrive 1 (279.37 GB, RAID 1, OK) [br] [br] physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, OK) [br] physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK) [br] Array B (SAS, Unused Space: 1 MB) [br] [br] logicaldrive 2 (1.09 TB, RAID 5, OK) [br] physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SAS HDD, 600 GB, OK) [br] physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 600 GB, OK, auto replace spare)
29
30># xxx ctrl all show status [br] [br] Smart Array P420 in Slot 1 Controller Status: OK [br] Cache Module Status: OK [br] Battery/Capacitor Status: OK
31
32># xxx ctrl all show status [br] [br] Smart Array P420 in Slot 1 Controller Status: OK [br] Cache Module Status: OK [br] Battery/Capacitor Status: Recharging[*1 배터리 충전중 [br] 서버를 재부팅 했거나 배터리 교체시 24시간동안 발생 할 수 있음 ]
33
34===# 비정상 출력 #===
35>HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PWXKV0CRHXXXXX) [br] [br] Internal Drive Cage at Port 1I, Box 3, OK [br] Internal Drive Cage at Port 2I, Box 3, OK [br] [br] Port Name: 1I (Mixed) [br] Port Name: 2I (Mixed) [br] [br] Array A (SAS, Unused Space: 0 MB) [br] logicaldrive 1 (279.37 GB, RAID 1, OK) [br] [br] physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, {{{#f00 Predictive Failure}}}[*2 Fail은 아니지만 곧 Fail 상태가 됨]) [br] physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK) [br] Array B (SAS, Unused Space: 1 MB) [br] [br] logicaldrive 2 (1.09 TB, RAID 5, OK) [br] physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SAS HDD, 600 GB, {{{#f00 Failed}}}[*3 Disk Fail 상태]) [br] physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 600 GB, OK, {{{#f00 active spaer for 1I:3:3}}}[*4 Dsik Fail로 인해 자동으로 Spaer 기능 작동 [br] 2개 이상 Fail시 정상 작동 하지 않는다.])
36