| r1 | ||
|---|---|---|
| r1 (새 문서) | 1 | [목차] |
| 2 | == 개요 == | |
| 3 | HP 서버 전용 점검 명령어를 정리한 문서이다. | |
| 4 | ||
| 5 | ||
| 6 | == Gen6~8 이하 명령어 == | |
| 7 | 디스크 점검 | |
| 8 | > hpacucli ctrl all show config | |
| 9 | ||
| 10 | 캐시배터리 점검 | |
| 11 | > hpacucli ctrl all show status | |
| 12 | ||
| 13 | == Gen9 서버 명령어 == | |
| 14 | 디스크 점검 | |
| 15 | > hpssacli ctrl all show config | |
| 16 | ||
| 17 | 디스크 점검 | |
| 18 | > hpssacli ctrl all show status | |
| 19 | ||
| 20 | == Gen10 서버 명령어 == | |
| 21 | 디스크 점검 | |
| 22 | > ssacli ctrl all show config | |
| 23 | ||
| 24 | 캐시배터리 점검 | |
| 25 | > ssacli ctrl all show status | |
| 26 | ||
| 27 | ===# 정상 출력 #=== | |
| 28 | ># xxx ctrl all show config [br] [br] HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PWXKV0CRHXXXXX) [br] [br] Internal Drive Cage at Port 1I, Box 3, OK [br] Internal Drive Cage at Port 2I, Box 3, OK [br] [br] Port Name: 1I (Mixed) [br] Port Name: 2I (Mixed) [br] [br] Array A (SAS, Unused Space: 0 MB) [br] logicaldrive 1 (279.37 GB, RAID 1, OK) [br] [br] physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, OK) [br] physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK) [br] Array B (SAS, Unused Space: 1 MB) [br] [br] logicaldrive 2 (1.09 TB, RAID 5, OK) [br] physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SAS HDD, 600 GB, OK) [br] physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 600 GB, OK, auto replace spare) | |
| 29 | ||
| 30 | ># xxx ctrl all show status [br] [br] Smart Array P420 in Slot 1 Controller Status: OK [br] Cache Module Status: OK [br] Battery/Capacitor Status: OK | |
| 31 | ||
| 32 | ># xxx ctrl all show status [br] [br] Smart Array P420 in Slot 1 Controller Status: OK [br] Cache Module Status: OK [br] Battery/Capacitor Status: Recharging[*1 배터리 충전중 [br] 서버를 재부팅 했거나 배터리 교체시 24시간동안 발생 할 수 있음 ] | |
| 33 | ||
| 34 | ===# 비정상 출력 #=== | |
| 35 | >HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PWXKV0CRHXXXXX) [br] [br] Internal Drive Cage at Port 1I, Box 3, OK [br] Internal Drive Cage at Port 2I, Box 3, OK [br] [br] Port Name: 1I (Mixed) [br] Port Name: 2I (Mixed) [br] [br] Array A (SAS, Unused Space: 0 MB) [br] logicaldrive 1 (279.37 GB, RAID 1, OK) [br] [br] physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, {{{#f00 Predictive Failure}}}[*2 Fail은 아니지만 곧 Fail 상태가 됨]) [br] physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK) [br] Array B (SAS, Unused Space: 1 MB) [br] [br] logicaldrive 2 (1.09 TB, RAID 5, OK) [br] physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SAS HDD, 600 GB, {{{#f00 Failed}}}[*3 Disk Fail 상태]) [br] physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 600 GB, OK) [br] physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 600 GB, OK, {{{#f00 active spaer for 1I:3:3}}}[*4 Dsik Fail로 인해 자동으로 Spaer 기능 작동 [br] 2개 이상 Fail시 정상 작동 하지 않는다.]) | |
| 36 | ||
| 37 | ># xxx ctrl all show status [br] [br] Smart Array P420 in Slot 1 Controller Status: OK [br] Cache Module Status: {{{#f00 Degraded}}}[*5 배터리 수명 노화로 서버가 느려짐 [br] 교체 권고 ] [br] Battery/Capacitor Status: Fail | |
| 38 | ||